Screw-Propelled Robot for Detecting Grease Pipe
Keywords:
Screw-propelled robot, Grease, Post-tension ductAbstract
In the nuclear reactor containment building, a post-tension duct is filled with grease to protect the steel strand from corrosion. A potential issue arises if the grease leaks due to a duct break, as this could lead to corrosion of the steel strand, posing a safety risk to the building. Therefore, it is essential to proactively inspect and prevent grease leaks. However, the current inspection method is inefficient, as it requires the removal of both the grease and the steel strand for inspection. Additionally, alternative methods for inspecting post-tension dust have not been thoroughly researched. In this research paper, we introduce a novel approach by developing a screw-propelled robot designed to navigate through the grease-filled duct and directly detect grease leaks. Furthermore, we have created a test environment that closely simulates a real post-tension duct within a containment building. We conducted experiments to evaluate the feasibility of our robot’s performance within the environment. The robot utilizes a twin screw mechanism to move both forward and backward within the grease duct, equipped with sensors to identify grease leakage and monitor strand corrosion.
References
Choi JH, Choi SJ, Yang DH, et al., 2019, Experimental Evaluation of Internal Blast Resistance of Prestressed Concrete Tubular Structure According to Explosive Charge Weight. KSCR Journal of Civil and Environmental Engineering Research, 39(3): 369–380. https://doi.org/10.12652/Ksce.2019.39.3.0369
Park JH, Hong JG, Lee BH, et al., 2007, Current Status of Domestic Nuclear Containment System and Inspection. Machines and Materials, 19(1): 40–49. http://www.koreascience.or.kr/article/JAKO200773336084508.page
Hong SH, Jung K, Lee JY, et al. 2013 10th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI), October 30–November 2, 2013: Development of Embedded Control System for Untethered In-Pipe Inspection Robot. 2013, Jeju, 67–70. https://doi.org/10.1109/URAI.2013.6677473
Lee KT, Lee JB, Kim JK, 2020, Grease Void Detection in the Post-Tensioning Duct. KCSE 2020 Convention, 2020: 1171–1172. https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE10569882
Gasch T, Ahmed L, Malm R, 2018, Instrumentation and Modelling of a Reactor Containment Building. Energiforsk. https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-235725
Kim D. Screw-Propelled Robot for Internal Inspection of Tendon Duct in Atomic Pile. 2022, Seoul National University of Science and Technology (SeoulTech).